							9M01B
							7/15/59
							Page 1.001
			9M01B

         MAIN FRAME DIAGNOSTIC AND RELIABILITY TEST
A. UNIT TESTED - 709 CPU
   1. Purpose of Test
      (a) Examine fixed-point and logical arithmetic, word transmission,
          shifting, control, and logical operations.
      (b) This program (9M01B) contains some routine modifications and
          additions to 9M01A.
   2. Method of Test
      (a) The program is divided in two parts under Sense Switch 5 Control.
      (b) This test employs a short version of 9DEPR which will interrogate
          sense switches and print a detailed account of error indications.
      (c) Refer to Sense Switch Control Section C-2 for an explanation of
	  Program Operation and Control.
B. MACHINE UNITS AND STORAGE AREA
   1. Units required
      MF, CF, DSU, CR, PR
   2. Storage locations
      00030-07767
C. PROGRAM CONTROL
   1. Deck
		000         9LDO1 Low End Loader
		001 - 184   Program Cards and Short Version 9DEPR
		185         Transfer Card TRA 00030
		186 - 187   2 Blank Cards
   2. Sense Switch Control
      Switch 1 UP		 Test Switch 4
      Switch 1 DOWN		 Repeat Routine
      Switch 2 UP		 Indicate Errors
      Switch 2 DOWN		 Bypass Errors
      Switch 3 UP		 Print errors if Switch 2 is UP
      Switch 3 DOWN		 Halt on error if Switch 2 is UP
      Switch 4 UP		 Proceed to next Routine
      Switch 4 DOWN		 Loop in Routine 50 times octal and then
				 proceed to next Routine
      Switch 5 UP		 Bypass long adder test and testing all
				 instructions requiring stops to determine
				 proper execution
      Switch 5 DOWN		 Perform long adder test and testing all
				 instructions requiring stops to determine
				 proper execution
      Switch 6 UP		 Call in next diagnostic
      Switch 6 DOWN		 Repeat test note program prints out
				 "100 Program Passes Complete 9M01"
				 every 100 passes if switch 3 is UP.
D. NORMAL STOPS
      06350 DVH Test
      06360 DVH Test
      06371 DVH Test
      06403 VDH Test
      06427 ENK Teat - Enter ones in keys
      06441 ENK Test - Enter zeros in keys

E. ERROR STOPS
      00035 Error in TSX inetruction
      00037 Error in TSX instruction
      07065 Error in Program with Switch 3 DOWN
        or
      07103 Display XRC for location of error-XRC has 2-s complement of
            error address

F. PRINTOUTS
    1. Program identification is printed out before starting the test if
       Switch 3 is UP.
    2. Program prints "100 Program Passes Complete 9M01" if Switch 3
       is UP and Switch 6 is DOWN,
    3. In an error printout, test LOC is Routine in Error, OPN is Instruction
       Being Tested and error ADR is Section of Routine in Error.
    4. Sample of the printout follows the write-ups.
    5. Consult the write-up for 9DEPR for a detailed account of the diagnostic
       print subroutine.

G. COMMENTS

    1. With Switch 5 depressed, the halt tests and the long adder tests are
       performed on the initial pass, On succeeding passes, the halt tests
       are bypassed.
    2. Prior to checking the contents of index registers after performing
       the STR instruction and Switch 3 is UP, any error encountered will alter
       the value 077707 octal initially placed in XRC.
    3. The decrement portion sf location 07701 contains the 2's complement of
       the last test address performed correctly.
    4. Although indexing has not been checked, it has been used sparingly
       because of space limitation in a 4K storage.
    5. The optional use of XRA is a feature of the convert instructions
       and is checked in this test. Since indexing has not been tested
       in 9M01, the C. E, should investigate the correct operation of
       index registers with any error in the CVR, CAQ or CRQ Routines
       where an instruction is tagged with XRA.
    6. It is possible for the program to appear to be operating error free
       although the machine is actually malfunctioning. To detect this case,
       Sense Switch 3 must be UP and Sense Swltch 6 DOWN. Under these
       conditions, the printer must print "100 Program Passes Complete 9M0l".
       Failure of the printout may indicate that E and I Time are coming up
       simultaneously in convert instructions.
    7. The Release of 9M01B makes 9MOlA cbsdete.

			LOCATIONS OF TE8T8
1.  CURSORY TSX		BEGINS AT		00034
2.  TOV			BEGINS AT		00041
3.  TNO			BEGINS AT		00066
4.  TZE			BEGINS AT		00112
5.  TNZ			BEGINS AT		00135
6.  ALS			BEGINS AT		00152
7.  ARS			BEGINS AT		00213
8.  LBT			BEGINS AT		00253
9.  PBT			BEGINS AT		00270
10. TPL			BEGINS AT		00307
11. TMI			BEGINS AT		00324
12. CLM			BEGINS AT		00341
13. SSP			BEGINS AT		00375
14. SSM			BEGINS AT		00413
15. CHS			BEGINS AT		00431
16. LLS			BEGINS AT		00447
17. LRS			BEGINS AT		00543
18. LGL			BEGINS AT		00632
19. RQL			BEGINS AT		00722
20. TBP			BEGINS AT		01002
21. NOP			BEGINS AT		01017
22. COM			BEGINS AT		01025
23. ADD			BEGINS AT		01064
24. ADM			BEGINS AT		01246
25. SUB			BEGINS AT		01312
26. SBM			BEGINS AT		01463
27. CLA			BEGINS AT		01527
28. CLS			BEGINS AT		01633
29. CAL			BEGINS AT		01670
30. ACL			BEGINS AT		01734
31. STO			BEGINS AT		02010
32. SLW			BEGINS AT		02020
33. STP			BEGINS AT		02044
34. STA			BEGINS AT		02156
35. STD			BEGINS AT		02216
36. CAS			BEGINS AT		02244
37. LDQ			BEGINS AT		02351
38. STQ			BEGINS AT		02376
39. SLQ			BEGINS AT		02425
40. TLQ			BEGINS AT		02464

41. RND			BEGINS AT		02541
42. MPY			BEGINS AT		02551
43. MPR			BEGINS AT		02717
44. DVP			BEGINS AT		02777
45. DCT			BEGINS AT		03045
46. DVH-NO HALTS	BEGINS AT		03114
47. ANA			BEGINS AT		03173
48. ANS			BEGINS AT		03262
49. ORA			BEGINS AT		03331
50. ORS			BEGINS AT		03413
51. TTR			BEGINS AT		03477
52. ETM AND LTM		BEGINS AT		03505
53. PSE SENSE LIGHTS	BEGINS AT		03742
54. MSE SENSE LIGHTS	BEGINS AT		03742
55. PSE SENSE SWITCHES	BEGINS AT		04047
56. STT			BEGINS AT		04114
57. STZ			BEGINS AT		04154
58. XCA			BEGINS AT		04204
59. XCL			BEGINS AT		04275
60. ERA			BEGINS AT		04372
61. LGR			BEGINS AT		04445
62. ZET			BEGINS AT		04533
63. NZT			BEGINS AT		04626
64. LAS			BEGINS AT		04713
65. VLM			BEGINS AT		04773
66. VDP			BEGINS AT		05214
67. VDH-NO HALTS	BEGINS AT		05411
68. CVR			BEGINS AT		05524
69. CAQ			BEGINS AT		05637
70. CRQ			BEGINS AT		06030
71. STL			BEGINS AT		06141
72. STR			BEGINS AT		06162

			SENSE SWITCH 5 DOWN

73. M06 ADDER TEST	BEGINS AT		06313
74. M07 ADDER TEST	BEGINS AT		06326
75. DVH-WITH HALTS	BEGINS AT		06346
76. VDH-WITH HALTS	BEGINS AT		06376
77. E NK		BEGINS AT		06427
78. LONG ADDER TEST	BEGINS AT		06452
79. MPY TEST		BEGINS AT		06521
80. MPY/DVP TEST	BEGINS AT		02541


			SAMPLE PRINTOUT


  NOW PERFORMING DIAGNOSTIC 9M01

TEST LOC 02464, OPN TLQ, ERROR LOC 02467, 0 LOC 000000003617, SW 009001 
LITE 0000, MQ 400000000003, XRA 00000, XRB 00000, XRC 75311, TRAP TGR 0
ACC +, Q 0, P, 0,000000000002, DIV CK 0, ACC OVFL 0,
INDS 000000000000, KEYS 002000002467

  100 PROGRAM PASSES COMPLETE 9M01 